Back to Home Page
Company | Production | Certifications | Site Map | Contact
 
IBS Serie L-H-A Oil/Air Cooler



Introduction:
Quick Choice
Selection Procedure
Ordering Code
On Line Catalog

IBS all aluminium heat exchange products for oil cooling applications are based on comprehensive component design standards , specific assembly technology & optimised material selection and specification to satisfy the increasing demands of the heat transfer sector.
The production process employed at IBS ensures consistently manufactured products of high quality in respect of structural , thermal , external cosmetic , internal cleanliness and corrosion resistance requirements.
IBS’s heat exchangers are totaly made by aluminium and all the parts are exactly designed starting from materials, thickness and design.
Fins has a special inclination to increase the performaces and to assure high cleanness.
Another important element is turbolator, that by its particolar profile, gives high resistant and performances.
Corrosion proof is obtained by special superficial treatment.
The innovative process to solder all the parts is named brazing. It develop in controlled atmosfere brazing furnace.
By this reason IBS’s heat exchangers have high performances and resistant like the best exchangers in the world market and they assure working pressure 25 bar, test pressure 35 BAR and max working temp 120°C.
Standard IBS’s series In this catalog there are three product lines as follow described:
• L series aluminium exchangers with AC,DC fans or hydraulic presetting made for low-medium power and flow
• H series aluminium exchangers with AC,DC fans or hydraulic presetting made for high power and flow
• A series aluminium exchangers with electric motor, pump and fan used for autonomous off-line cooling.
Fluid compatibility: Mineral oil HL/HLP,DIN 51524, water/oil emulsion HFA,HFB,CETOP,RP//H, water-glicol HFC,CETOP RP 77H, Esters fosphates HFD-R,CETOP RP 77H.
For corrosive atmosfere or fluid with viscosity greater than 100cst, contact IBS.

Air Side
Oil Side

 

Installation:

The IBS technical group would be pleased to advise customers on all aspects of their product range to ensure optimised installation is achieved for best inservice life.
When install heat exchanger, be sure to have the right air flow; minimum distance should be greater than half exchanger height. Is recommended to use flexible units to preserve the exchanger from solicitations.

Maintenance:

Dependant on each specific application attention must be paid to external and internal material surfaces to prevent unecessary soiling and contamination build-up which in turn would adversly affect the thermal performance of the cooler.
Cleaning of external surfaces to remove debris can usually be effected by controlled compressd air or low pressure water jetting.
Care must be taken not to directly impinge onto the fin corrugations to prevent fin deflection damage.internally a controlled flushing operation with a compatible biodegradable detergent is usually adequate to remove any residual surface build-up.
To preserve heat exchanger, it is suggest that a by-pass valve is inserted.